[口头报告]High-precision measurement of 36SF5+ signal using the MAT 253 Ultra isotope-ratio mass spectrometer

High-precision measurement of 36SF5+ signal using the MAT 253 Ultra isotope-ratio mass spectrometer
编号:1326 稿件编号:1062 访问权限:仅限参会人 更新:2024-04-11 14:43:39 浏览:440次 口头报告

报告开始:2024年05月18日 13:39 (Asia/Shanghai)

报告时间:12min

所在会议:[S2] 主题2、地球化学 » [S2-1] 主题2、地球化学 专题2.1、专题2.3(18日下午,4F观海厅1)

暂无文件

摘要
Rationale: The Δ36S standard deviation (SD) measured in a conventional isotope-ratio mass spectrometer (IRMS) such as MAT 253 is at c.a. 0.1‰ to 0.3‰. At this precision, it is difficult to resolve the origin of non-mass-dependent sulfur (NMD-S) isotope fractionation in the tropospheric sulfate aerosol and in Martian meteorites or small deviations from the canonical mass-dependent fractionation laws. Interfering ions (originated from fluorination and/or mass spectrometer ion source itself) with m/z at 131 of 36SF5+ by the community as the cause of the poor precision, but the exact ion species has not been identified or confirmed.
Methods: Here we examined the potential interfering ions by using the Thermo Scientific MAT 253 Ultra, a high-resolution (mass resolving powers up to 40,000) stable isotope-ratio mass spectrometer, to measure the SF6 working gas and SF6 gases converted from IAEA-S1 Ag2S reference materials via a fluorination system.
Results: We found that there is a resolvable peak to the right of the 36SF5+ peak for both the SF6 working gas and SF6 generated by the fluorination system. The peak is identified as the 12C3F5+ ion, generated inside the instrument during the ionization process. By minimizing the presence of carbon-bearing compounds (e.g., organic matter in sample or helium gas, glue or o-ring in sample tubes, or carbon-bearing gases inside the mass spectrometer), we were able to achieve a Δ36S SD of 0.046‰ (n=8) for SF6 zero-enrichment and 0.069‰ (n=8) for overall measurement start from sliver sulfide IAEA-S1.
Conclusions: Minimizing the presence of carbon-bearing compounds and avoiding the interfering signals from 36SF5+ via MAT 253 Ultra high‐resolution isotope-ratio mass spectrometer, we can improve Δ36S measurement precision by 2 to 5 folds, which helps to open new territories for research using quadruple sulfur isotope composition.
 
 
关键字
non-mass-dependent sulfur (NMD-S) isotope fractionation,interfering ions,Δ36S measurement precision
报告人
孙翔
博士研究生 南京大学

稿件作者
孙翔 南京大学
仝凤台 南京大学
彭永波 南京大学 地球科学与工程学院;南京大学 国际同位素效应研究中心
鲍惠铭 南京大学
发表评论
验证码 看不清楚,更换一张
全部评论
● 会务总协调  

● 学术安排

 

辜克兢

13950003604

gukejing@xmu.edu.cn

辜克兢

13950003604

gukejing@xmu.edu.cn

柳    欣

13806024185

liuxin1983@xmu.edu.cn

窦    恒

18627754021

douheng@chytey.com

孙佳妮

15201086188

scarlett@chytey.com

刘    琳

13313708075

lliu@iue.ac.cn

 

● 会场技术服务

 

李    虎

柳    欣

18965842343

13806024185

hli@iue.ac.cn

liuxin1983@xmu.edu.cn
李招英

13860473552

lizhaoying@xmu.edu.cn

     
           
● 会场安排   ● 会议注册  

辜克兢

13950003604

gukejing@xmu.edu.cn

胡勤梅 13554192326

mary@chytey.com

窦    恒

18627754021

douheng@chytey.com

孙晓笛 18813296455 xiaodi.sun@xmu.edu.cn
           
● 商业赞助   ● 会议财务  
朱    佳 13950159036

zhujia@xmu.edu.cn

许心雅 0592-2880181 xuxinya@xmu.edu.cn
           

海报张贴

 

● 酒店预定及咨询

 
张    君 13860426122 junzhang@xmu.edu.cn

李    璟

18627754146

lijing@chytey.com

卢    巍 18971567453 luwei@chytey.com      

 

登录 注册缴费 酒店预订